Technology: Light Scattering
Particle Size: 0.1 to 10µm micrometer
Density Range: 0.001 to 10 mg/m3
Data Logging: 0 to 100,000
Interface: USB, 0 to 1V Analog, Pulse, Alarm
Other Probes: N/A
Power Supply: 6AA or AC Adapter
Applications: IAQ Investigations, Industrial Hygiene, Occupational Health & Safety, Contamination Exposure Monitoring, Manufacturing Process Control |
|
|
|
|
|
|
|
Technology: Nano Condensation
Particle Size: 15nm, 15 nanometer
Density Range: 0 to 100,000 particles/cm3
Data Logging: Programmable
Interface: USB
Other Probes: N/A
Power Supply: AA batteries or AC Adapter
Applications: Indoor Air Quality Investigation, Aerosol Research, Filter Test, Environmental Monitoring for Electronics, Food Processing, Pharmaceutical |
|
|
|
|
|
|
|
Technology: LASER Diode
Particle Size: 5 particle sizes; 0.3, 0.5, 1.0, 3.0, 5.0 µm micrometer in CuFt or m^3
Density Range: Flow 0.1CFM +/- 10%
Data Logging: 0 to 500
Interface: RS232C
Other Probes: Optional Temperature + Relative Humidity and Air Velocity probes, 4 simultaneous parameters
Power Supply: 4AA, AC Adapter
Applications: Cleanroom verification, Clean Bench verification, IAQ Investigation, Food Process Investigation, Hospital Surgical Room, Filter Testing |
|
|
|
|
|
|
|
Technology: LASER Diode
Particle Size: 0.3, 0.5, 5.0 µm micrometer
Density Range: Flow 0.1CFM
Data Logging: 0 to 10000
Interface: RS232C
Other Probes: N/A
Power Supply: 4AA, AC Adapter
Applications: Cleanroom verification / monitoring, Clean Bench verification, IAQ Investigation, Food Process Investigation, Hospital Surgical Room, Filter Testing |
|
|
|
|
|
|
|
Technology: Toxic Gas Probe
Particle Size: CO and CO2
Density Range: CO 0 to 500PPM and CO2 0 to 5000PPM
Data Logging: Yes
Interface: RS232C, 0 to 1V
Other Probes: Relative Humidity, Thermometer
Power Supply: 4AAA
Applications: IAQ Investigation, Ventilation Testing, Thermal Comfort Control, Monitoring Toxic Gas |
|
|
|
|
|
|
|
Technology: Piezobalance
Particle Size: Model 3521:<10 µm, Model 3522 < 2.5µm
Density Range: 0.01 to 10 mg/m3
Data Logging: 0 to 500
Interface: RS-232C
Other Probes: N/A
Power Supply: AC or Batteries
Applications: IAQ Investigations, Industrial Hygiene, Occupational Health & Safety, Product Quality Control, Laboratory Research
|
|
|
|
|
|
|
|
Technology: Laser Diode
Particle Size: 0.3, 0.5, 1.0, 3.0, 5.0, 10.0µm micrometer
Density Range: 50 LPM
Data Logging: 0 to 10,000
Interface: Ethernet, USB, Memory card slot (MMC)
Other Probes: Airflow, Temperature, Humidity, Differential Pressure
Power Supply: AC Adapter, Batteries
Applications: Simultaneous measurements of 6 particle sizes, Compliant with ISO 21501-4 and 21 CFR Part 11, Clean Room verification, Clean Bench verification, Filter Testing, Facility Certification, Food Process Investigation, Hospital Surgical Room, 2 Year Warranty
|
|
|
|
|
|